Model | Error Code | Problem Description | Corrective Action Options |
---|---|---|---|
T1100 | 13.1:YZ | The ISS cable may be not properly connected or malfunctioning. | Turn off/on. Removce ALL cartridges and reinstall, check cables between ink supply station and main PCA, replace ink supply station, replace main pca |