T2300 |
42:YZ |
Electrical problem in Scan-Axix Motor |
Turn off/on. Open scanner for visible obstacles. Check Scan-Axis Motor cale, replace Scan-axis Motor, Replace Engine PCA |
T1100 |
42:YZ |
Electrical fault or current limit in Scan-Axis Motor.. |
Turn off/on. Check for visable obstacles, perform Scan Axis Diagnostic Test, Check cable, repalce PrintMech PCA, Replace Scan-Axix Motor, Replace PrintMech PCA |
T610 |
42:YZ |
Electrical fault or current limit in Scan-Axis Motor.. |
Turn off/on. Check for visable obstacles, perform Scan Axis Diagnostic Test, Check cable, repalce PrintMech PCA, Replace Scan-Axix Motor, Replace PrintMech PCA |
Z5200 |
42:YZ |
Electrical fault or current limit in Scan-Axis Motor. |
Reboot. Check for Visable Obstacles , clear obstructions, perform Scan Axis diagnostic test, check cables, replace Scan Axis Motor, replace the PrintMech PCA |